  Datasheet File OCR Text:
  confidential document page: 1 / 21 data image corporation lcd module specification item no.: GM126401SFAYA-R1 table of contents 1. cover & contents ??????????????????????????????????????????????? 1 2. record of revision ????????????????????????????????????????????? 2 3. general specifications ?????????????????????????????????????? 3 4. absolute maximum ratings ??????????????????????????????? 4 5. electrical characteristics ?????????????????????????????? 6 6. electro-optical characteristic ?????????????????????? 6 7. timing characteristics ????????????????????????????????????? 9 8. pin connections ?????????????????????????????????????????????????? 11 9. power supply ??????????????????????????????????????????????????????? 11 10. block diagram ???????????????????????????????????????????????????? 12 11. quality assurance ????????????????????????????????????????????? 14 12. lot numbering system ??????????????????????????????????????? 18 13. lcm numbering system ??????????????????????????????????????? 18 14. precautions in use lcm ????????????????????????????????????? 19 15. outline drawing ?????????????????????????????????????????????????? 20 16 package information ????????????????????????????????????????? 21 r&d dept. q.c. dept. eng. dept. prod. dept. version: issued date: sheet code: total pages: b 2003/4/1 21
confidential document page: 2 / 21 2. record of revision rev date item page comment b aug/02/02 11.2.3, 11.3 16-17 1.change: 11.2.3 inspection parameters. 2. add on11.3 sampling increase condition. aug/02/02 13 18 new model numbering system is updated from old p/n# gm12641ds1l1y-02 b apr/01/03 15 20 modify: outline drawing.
confidential document page: 3 / 21 3. general specification display format : 128 (w) 64 (h) dots dot size : 0.48 (w) 0.48 (h) mm view area : 72.5 (w) 39.5 (h) mm general dimensions : 93 (w) 70 (h) 12.5 (t) mm max. weight : 83 g max. v lcd type : stn gray stn yellow fstn v polarizer mode : reflective transflective transmissive negative v view angle : 6 o?clock 12 o?clock others v backlight : led el ccfl v backlight color : yellow green amber blue green white others controller / driver : ks0107/ks0108 v normal wide temperature operating 0 to 50 c operating -20 to 70 c temperature range : storage -20 to 70 c storage -30 to 80 c
confidential document page: 4 / 21 4. absolute maximum ratings 4.1 electrical absolu te maximum ratings v ss = 0v, ta = 25 c item symbol min. max. unit supply voltage (logic) v dd -v ss 0 8 v supply voltage (lcd driver) v dd -v o 0 16.5 v input voltage v i v ss-0.3 v dd+0.3 v operating temperature t op 0 50 c storage temperature t stg -20 70 c 4.2 environmental abso lute maximum ratings operating storage item (min.) max.) (min.) (max.) comment ambient temp 0 50 -20 70 note (1) humidity note (2) note(2) without condensation vibration -- 4.9m/s 2 -- 19.6m/s 2 xyz direction shock -- 29.4m/s 2 -- 490m/s 2 xyz direction note(1) ta = 0 c : 50hr max. note(2) ta 40 c : 90% rh max. ta 40 c : absolute humidity must be lower than the humidity of 90% rh at 40 c .
confidential document page: 5 / 21 4.3 electronic static discharge maximum rating esd test method : iec1000-4-2 item description testing environment ambient temperature :15 c to 35 c humidity: 30% to 60 % lcm ( e.u.t ) : power up testing equipment manufacture: noise ken, model no. esd-100l testing condition see drawing 1 direct discharge 0 to 6 kv discharge point, see drawing 2 indirect discharge 0 to 12kv discharge point, see drawing 1 pass condition no malfunction of unit. temporary malfunction of unit which can be recovered by system reset fail condition non. recoverable malfunction of lcm or system (1) (2) direct discharge hcp indirect discharge ground level vcp indirect discharge hcp isolator esd power supply wooden table(tall 0.8m) 470k fig 1 esd testing equipment a b d c direct contact discharge contact point : a.b.c.d
confidential document page: 6 / 21 5. electrical characteristics item symbol condition min. typ. max. unit supply voltage (logic) v dd -v ss 4.5 5.0 5.5 v 0 c 9.0 9.5 10.0 25 c 8.6 9.3 9.7 supply voltage (lcd) v dd -v o 50 c 8.2 8.8 9.2 v v ih 0.7v ss -- v dd input voltage v il -- v ss -- 0.3v dd v logic supply current i dd v dd -v ss =5v -- 3.8 6 ma 6. electro-optica l characteristics item symbol condition min. typ. max. unit ref. 0 c -- 400 600 rise time tr 25 c -- 110 170 ms 0 c -- 500 800 fall time tf 25 c -- 110 170 ms note (1) contrast cr 25 c -- 3 -- note (3) 60 -- -- view angle 1 ~ 2 ? 1, ? 2 25 c & cr 1.5 -30 -- 30 note (2) frame frequency ff 25 c -- 64 -- hz note (1) & (2) : see next page note (3) : contrast ratio is defined under the following condition: cr= brightness of non-selected condition brightness of selected condition ( a ). temperature ---------- 25 c ( b ). frame frequency ---- 64hz ( c ). viewing angle -------- = 0 , ? = 0 ( d ). operating voltage --- 9.3v
confidential document page: 7 / 21 note (1) response time is measured as the shortest period of time possible between the change in state of an lcd segment as demonstrated below: +vop 1/f f 0 -vop 90% 100% 10% t r t f condition: ( a ) . temperature ---------------25 c ( b ) . frame frequency --------- 64hz ( c ) . view angle ----------------- = 0 , ? =0 ( d ) . operating voltage -------- 9.3v note (2) definition of view angle top ? bottom direction right -- left direction top ? 2 ? 1 1 2 bottom left right
confidential document page: 8 / 21 6.1 led ele ctro-optical characteristic ta = 25 c item symbol condition min. typ. max. unit forward voltage v f if = 330ma yellow green -- 4.2 4.6 v luminous intensity i v if = 330ma yellow green 120 180 -- cd/m 2 peak emission p if = 330ma yellow green -- 570 -- nm spectrum radiation ? if = 330ma yellow green -- 30 -- nm reverse current ir vr = 8v yellow green -- -- 0.2 ma note : measured at the led backlight unit. 6.2 led maxim um operating range item symbol yellow green unit power dissipation p ad 2.3 w forward current i af 495 ma reverse voltage vr 8 v 6.2.1 led array block diagram a 2 dies x33 =66 k
confidential document page: 9 / 21 7. timing characteristics mpu interface characteristic symbol min typ max unit e cycle t c 1000 -- -- ns e high level width t wh 450 -- -- ns e low level width t wl 450 -- -- ns e rise time t r -- -- 25 ns e fall time t f -- -- 25 ns address set-up time t asu 140 -- -- ns address hold time t ah 10 -- -- ns data set-up time t su 200 -- -- ns data delay time t d -- -- 320 ns data hold time (write) t dhw 10 -- -- ns data hold time (read) t dhr 20 -- -- ns
confidential document page: 10 / 21 t c e 2.0v 0.8v t wl t wh t r t f r/w t asu t ah t asu t ah cs1-cs2,rs 0.8v 2.0v t dsu t dh db0-7 mpu write timing t c e t wl t wh t k t f r/w t asu t ah t asu t ah cs1,cs2,rs t d t dh db0-7 mpu read timing
confidential document page: 11 / 21 8. pin connections no. symbol function 1 v ss ground (0v) 2 v dd +5v 3 v 0 power supply for lcd drive 4 d/i l instructions h data 5 r/w h data read (lcd mpu) l data write (lcd mpu) 6 e enable signal 7 db0 8 db1 9 db2 10 db3 11 db4 12 db5 13 db6 14 db7 data bus line 15 cs1 chip select for ic1, active high 16 cs2 chip select for ic2, active high 17 /rst reset, active low 18 v ee negative voltage output 19 ledk led cathode. power supply - 20 leda led anode. power supply + 9. power supply vdd +5v lcm vss vr=10k vo led a backlight 0v led k vee
confidential document page: 12 / 21 10. block diagram common 64com lcd panel drive 128 64 dots vss lcd vdd dc to dc 64seg 64seg vee ( - 5 v ) v0 segment segment r/w d/i driver 1 driver 2 e db0 db7 cs1 cs2 10k /rst
confidential document page: 13 / 21 display control instruction the display control instructions control the internal state of the ks0108b . instruction is received from mpu to ks0108b for the disp lay control. the following table shows various instructions. instruction rs r/w db7 db6 db5 db4 db3 db2 db1 db0 function display on/off l l l l h h h h h l/h controls the display on or off. internal status and display ram data is not affected. l : off, h : on set address l l l h y address (0-63) sets the y address in the y address counter. set page (x address) l l h l h h h page (0-7) sets the x address at the x address counter. display start line l l h h display start line (0-63) indicates the display data ram displayed at the top of the screen status read l h b u s y l on / off r e s e t l l l l read status. busy l: ready h: in operation on/off l: display on h: display off reset l: normal h: reset write display data h l write data writes data (db0:7)into display data ram. after writing instruction, y address is increased by 1 automatically. read display data h h read data read data (db0:7) from display data ram to the data bus.
confidential document page: 14 / 21 11. quality assurance 11.1 test condition 11.1.1 temperature and humidity(ambient temperature) temperature : 20 5 c humidity : 65 5% 11.1.2 operation unless specified otherwise, test will be conducted with lcm in operation. 11.1.3 container unless specified otherwise, vibration te st will be conducted on module only. 11.1.4 test frequency single cycle. 11.1.5 test method no. parameter conditions regulations 1 high temperature operating 50 2 c note 3 2 low temperature operating 0 2 c note 3 3 high temperature storage 70 2 c note 3 4 low temperature storage -20 2 c note 3 5 vibration test (non-operation state) total fixed amplitude : 1.5mm vibration frequency : 10 ~ 55hz one cycle 60 seconds to 3 directions of x.y.z. for each 15 minutes note 3 6 damp proof test (non-operation state) 40 c 2 c, 90~95%rh, 96h note 1,2 7 shock test (non-operation state) to be measured after dropping from 60cm high once concrete surface in packing state note 3 note 1: returned under normal temperature and humidity for 4 hrs. note 2: no dew condensation to be observed. note 3: no change on display and in operation under the test condition
confidential document page: 15 / 21 11.2 inspectio n condition 11.2.1 inspection conditions the lcd shall be inspected under 40w white fluorescent light. 45 11.2.2 definition of applicable zones b lcd a bezel pcb a : display area b : non-display area
confidential document page: 16 / 21 11.2.3 inspection parameters no. parameter criteria 1 black or white spots acceptable number zone dimension a b class of defects aql level d < 0.15 ? ? 0.15 d< 0.2 4 4 0.2 d 0.25 2 2 d 0.3 0 1 minor 2.5 d = (long + short) / 2 * : disregard 2 scratch, substances acceptable number x (mm) zone y(mm) a b class of defects aql level ? 0.04 w ? ? 3.0 l 0.06 w 4 4 2.0 l 0.08 w 2 3 ? 0.1 < w 0 1 minor 2.5 x : length y : width ? : disregard total defects should not exceed 4/module 3 air bubbles (between glass & polarizer) acceptable number zone dimension a b class of defects aql level d 0.15 ? ? 0.15 < d 0.25 2 ? 0.25 < d 0 1 minor 2.5 ? : disregard total defects shall not excess 3/module. 4 uniformity of pixel (1) pixel shape (with dent) 0.152
confidential document page: 17 / 21 4 uniformity of pixel (2) pixel shape ( with projection) should not be connected to next pixel 0.152 (3) pin hole x y ( x + y )/2 0.02mm (less than 0.1 mm is no counted) (4) deformation x ( x + y ) / 2 0.3mm y total acceptable number : 1/pixel, 5/cell definition major aql 0.65% it is a defect that is likely to result in failure or to reduce materially the usability of the product for the intended function. aql 1.00% it is a defect that is likely to assembly size and not result in functioning problem. class of defects minor aql 2.5% it is a defect that will not result in functioning problem with deviation classified. 11.3 sampling condition unless otherwise agree in written, the sampling inspection shall be applied to the incoming inspection of customer. lot size: quantity of shipment lot per model. sampling type: normal inspection, single sampling inspection level: level ii sampling table: mil-std-105e
confidential document page: 18 / 21 12. lot numbering system 9 7 4 2 production week number production year 13. lcm numbering system gm 126401 s f a y a ? r1 version :r1 view direction & temp. range a?bottom view 6h & normal temp. b?bottom view 6h & wide temp. c?top view & normal temp. d?top view & wide temp. backlight color b ?blue a ?amber y - yellow backlight s ?edge light led b/l e ?el a ?array led b/l mode m ? transmissive r ? reflective f ? transflective n - negative lcd type g ?stn gray s ? stn yellow n ? tn series code 1264 01 ?128 dots x 64 dot, 0 lcd type, 1 pcb type model type cm ? character module gm ? graphic module cx ? custom character module gx ? custom graphic module
confidential document page: 19 / 21 14. precaution for using lcm 1. liquid crystal display (lcd) lcd is made up of glass, organic sealant, organic fluid, and polymer based polarizers. the following precautions should be taken when handing, (1). keep the temperature within range of use and storage. excessive temperature and humidity could cause polarization degredation, polarizer peel off or bubble. (2). do not contact the exposed polarizers with anything harder than an hb pencil lead. to clean dust off the display surface, wipe gently with cotton, chamois or other soft material soaked in petroleum benzin. (3). wipe off saliva or water drops immediately. contact with water over a long period of time may cause polarizer deformation or color fading, while an active lcd with water condensation on its surface will cause corrosion of ito electrodes. (4). glass can be easily chipped or cracked from rough handling, especially at corners and edges. (5). do not drive lcd with dc voltage. 2. liquid crystal display modules 2.1 mechanical considerations lcm are assembled and adjusted with a high degree of precision. avoid excessive shocks and do not make any alterations or modifications. the following should be noted. (1). do not tamper in any way with the tabs on the metal frame. (2). do not modify the pcb by drilling extra holes, changing its outline, moving its components or modifying its pattern. (3). do not touch the elastomer connector, especially insert an backlight panel (for example, el). (4). when mounting a lcm make sure that the pcb is not under any stress such as bending or twisting . elastomer contacts are very delicate and missing pixels could result from slight dislocation of any of the elements. (5). avoid pressing on the metal bezel, otherwise the elastomer connector could be deformed and lose contact, resulting in missing pixels. 2.2. static electricity lcm contains cmos lsi?s and the same precaution for such devices should apply, namely (1). the operator should be grounded whenever he/she comes into contact with the module. never touch any of the conductive parts such as the lsi pads, the copper leads on the pcb and the interface terminals with any parts of the human body. (2). the modules should be kept in antistatic bags or other containers resistant to static for storage. (3). only properly grounded soldering irons should be used. (4). if an electric screwdriver is used, it should be well grounded and shielded from commutator sparks. (5) the normal static prevention measures should be observed for work clothes and working benches; for the latter conductive (rubber) mat is recommended. (6). since dry air is inductive to static, a relative humidity of 50-60% is recommended. 2.3 soldering (1). solder only to the i/o terminals. (2). use only soldering irons with proper grounding and no leakage. (3). soldering temperature : 280 c 10 c (4). soldering time: 3 to 4 sec. (5). use eutectic solder with resin flux fill. (6). if flux is used, the lcd surface should be covered to avoid flux spatters. flux residue should be removed after wards. 2.4 operation (1). the viewing angle can be adjusted by varying the lcd driving voltage v0. (2). driving voltage should be kept within specified range; excess voltage shortens display life. (3). response time increases with decrease in temperature. (4). display may turn black or dark blue at temperatures above its operational range; this is (however not pressing on the viewing area) may cause the segments to appear ?fractured?. (5). mechanical disturbance during operation (such as p ressing on the viewing area) may cause the segments to appear ?fractured?. 2.5 storage if any fluid leaks out of a damaged glass cell, wash off any human part that comes into contact with soap and water. never swallow the fluid. the toxicity is extremely low but caution should be exercised at all the time. 2.6 limited warranty unless otherwise agreed between data image and customer, data image will replace or repair any of its lcd and lcm which is found to be defective electrically and visually when inspected in accordance with data image acceptance standards, for a period on one year from date of shipment. confirmation of such date shall be based on freight documents. the warranty liability of data image is limited to repair and/or replacement on the terms set forth above. data image will not responsible for any subsequent or consequential events.
confidential document page: 20 / 21 15 outline drawing
confidential document page: 21 / 21 16. package information anti-static bag module


▲Up To Search▲   

 